{"id":11872,"date":"2021-08-20T16:49:05","date_gmt":"2021-08-20T16:49:05","guid":{"rendered":"https:\/\/polywaterv2.wpengine.com\/?p=11872"},"modified":"2023-12-01T14:50:19","modified_gmt":"2023-12-01T20:50:19","slug":"medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater","status":"publish","type":"post","link":"https:\/\/www.polywater.com\/es\/knowledge-hub\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\/","title":{"rendered":"Medici\u00f3n de la fricci\u00f3n en la tabla de fricci\u00f3n de Polywater"},"content":{"rendered":"<div id=\"vyLightbox\"><\/div>\n<h2><strong>Medici\u00f3n de la fricci\u00f3n en la tabla de fricci\u00f3n de Polywater<\/strong><\/h2>\n<p>Polywater\u00ae ha medido el coeficiente de fricci\u00f3n de miles de combinaciones de cables, conductos y lubricantes utilizando la tabla de fricci\u00f3n.\u00a0 La mayor\u00eda de nuestros lubricantes para tendidos se optimizaron usando este dispositivo.<\/p>\n<p>Trabajamos con fabricantes de cables y conductos as\u00ed como con usuarios finales para desarrollar informaci\u00f3n fiable sobre el coeficiente de fricci\u00f3n. A su vez, hemos desarrollado una extensa base de datos de coeficientes de fricci\u00f3n. Cada valor publicado es un promedio de m\u00faltiples pruebas y representa un amplio conjunto de trabajos. Los datos recopilados durante a\u00f1os de pruebas con la tabla de fricci\u00f3n son la fuente principal de la base de datos de fricci\u00f3n en el software <a href=\"https:\/\/www.polywater.com\/es\/pull-planner\/\" target=\"_blank\" rel=\"noopener\">Pull-Planner\u2122 de Polywater<\/a>.<\/p>\n<table style=\"width: 100%; border: 3px solid #273A80; background-color: #69c3e8; margin: 15px 0px 15px 0px;\">\n<tbody>\n<tr>\n<td style=\"padding: 20px; text-align: center;\"><a href=\"https:\/\/www.polywater.com\/es\/knowledge-hub\/coeficiente-de-friccion-en-el-tirado-de-cables-parte-1\/\"><strong>Contenido relacionado: <\/strong>Coeficiente de fricci\u00f3n en el tirado de cables \u2014 Parte 1<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong>C\u00f3mo funciona la tabla de fricci\u00f3n<\/strong><\/h2>\n<p>La tabla b\u00e1sica de fricci\u00f3n se muestra a continuaci\u00f3n:<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-11873\" src=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Chart-1-ES.jpg\" alt=\"Chart 1 ES\" width=\"700\" height=\"374\" srcset=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Chart-1-ES.jpg 2237w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Chart-1-ES-300x160.jpg 300w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Chart-1-ES-1024x547.jpg 1024w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Chart-1-ES-768x410.jpg 768w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Chart-1-ES-1536x820.jpg 1536w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Chart-1-ES-2048x1093.jpg 2048w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/p>\n<p>Las mediciones se realizan deslizando una secci\u00f3n de cable de 6 pulgadas (152 mm) sobre un conducto dividido. Todos los materiales se limpian y se hace la medida de control sin lubricaci\u00f3n. Luego el cable y el conducto son recubiertos con una pel\u00edcula delgada de lubricante para determinar el coeficiente de fricci\u00f3n lubricado. Si se prueba m\u00e1s de un lubricante, el cable y el conducto se limpian o intercambian con materiales frescos para que el valor sin lubricar coincida con el control inicial. Un cilindro de presi\u00f3n neum\u00e1tico empuja hacia abajo el cable. Una c\u00e9lula de carga mide esta fuerza normal. Un cabrestante peque\u00f1o tira del conducto a una velocidad constante de 23 pies\/min (7 m\/min). Tenga en cuenta que el conducto pasa bajo el cable. Esto no afecta de ninguna manera a la determinaci\u00f3n de la fricci\u00f3n y permite recopilar datos con un trozo de cable relativamente peque\u00f1o. Una segunda c\u00e9lula de carga mide la fuerza de tracci\u00f3n. Ambas mediciones de las c\u00e9lulas de carga son al mismo tiempo capturadas por una balanza de la c\u00e9lula de carga, que realiza lecturas cada 0,1 segundos. El coeficiente cin\u00e9tico de fricci\u00f3n se calcula a partir de estos datos utilizando la siguiente ecuaci\u00f3n:<\/p>\n<p><strong>\u03bc = F\/N<\/strong><\/p>\n<p>Donde:<\/p>\n<p><strong>\u03bc es el coeficiente de fricci\u00f3n<\/strong><br \/>\n<strong>F es la fuerza de tracci\u00f3n medida<\/strong><br \/>\n<strong>N es la fuerza normal medida<\/strong><\/p>\n<p>Extraemos veinte (20) puntos de datos de la parte central de la prueba y estos se promedian para el valor final de coeficiente de fricci\u00f3n. Si la desviaci\u00f3n est\u00e1ndar es superior a 0,02 con lubricaci\u00f3n o 0,04 sin lubricaci\u00f3n, el tramo se descarta. Los resultados registrados son el promedio de tres o cuatro tendidos independientes. Los datos reales utilizados para desarrollar un \u00fanico valor de coeficiente de fricci\u00f3n se muestran a continuaci\u00f3n.<\/p>\n<p><strong>Gr\u00e1fico 1<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-11877\" src=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-1.png\" alt=\"Grafico 1\" width=\"700\" height=\"363\" srcset=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-1.png 963w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-1-300x156.png 300w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-1-768x399.png 768w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/p>\n<p>La variaci\u00f3n de coeficiente de fricci\u00f3n en tendidos de poca distancia y de tendido a tendido se recoge en el gr\u00e1fico anterior y tiende a ser relativamente baja.<\/p>\n<h2><strong>Fricci\u00f3n cin\u00e9tica frente a est\u00e1tica<\/strong><\/h2>\n<p>La tabla de fricci\u00f3n de Polywater est\u00e1 configurada para medir la fricci\u00f3n cin\u00e9tica o de deslizamiento. El muestreo de datos discretos que registramos proh\u00edbe determinar la fricci\u00f3n est\u00e1tica. En cualquier caso, los resultados de fricci\u00f3n cin\u00e9tica son los m\u00e1s \u00fatiles y proporcionan la mejor correlaci\u00f3n con la tensi\u00f3n medida en los tendidos de cables de campo. Algunas cubiertas \u00absin lubricaci\u00f3n\u00bb muestran una variaci\u00f3n significativa entre la fricci\u00f3n est\u00e1tica y cin\u00e9tica, lo que resulta en \u00abdeslizamientos\/adherencias\u00bb (salto de cable) en el tendido.<\/p>\n<table style=\"width: 100%; border: 3px solid #273A80; background-color: #69c3e8; margin: 15px 0px 15px 0px;\">\n<tbody>\n<tr>\n<td style=\"padding: 20px; text-align: center;\"><a href=\"https:\/\/www.polywater.com\/es\/knowledge-hub\/medicion-de-la-friccion-de-traccion-del-cable-con-una-prueba-de-carrete\/\"><strong>Contenido relacionado: <\/strong>Medici\u00f3n de la fricci\u00f3n de tracci\u00f3n del cable con una prueba de carrete<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong>An\u00e1lisis estad\u00edstico<\/strong><\/h2>\n<p>Hay otra fuente de variaci\u00f3n que puede ser m\u00e1s significativa. Esta es la variaci\u00f3n con respecto a varias cubiertas del cable en la misma clase gen\u00e9rica. Las cubiertas polim\u00e9ricas pueden diferir en formulaci\u00f3n y propiedades f\u00edsicas de un fabricante a otro. Los conductos met\u00e1licos tambi\u00e9n muestran una mayor variaci\u00f3n.<\/p>\n<p>La base de datos de Polywater representa m\u00e1s de una d\u00e9cada de datos recopilados. Las variaciones en los resultados individuales reflejan las diferencias mencionadas anteriormente. Como ejemplo, el Gr\u00e1fico 2 a continuaci\u00f3n muestra la distribuci\u00f3n normal para varias pruebas de cable con cubierta de LLDPE en tres tipos de conductos diferentes. Los datos del coeficiente de fricci\u00f3n en el acero muestran una mayor distribuci\u00f3n de los datos que los conductos de EMT o PVC.<\/p>\n<p><strong>Gr\u00e1fico 2<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-11882\" src=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-2.png\" alt=\"Grafico 2\" width=\"700\" height=\"431\" srcset=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-2.png 1745w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-2-300x185.png 300w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-2-1024x631.png 1024w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-2-768x473.png 768w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-2-1536x946.png 1536w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/p>\n<p>Los datos de coeficiente de fricci\u00f3n ofrecidos en nuestra documentaci\u00f3n y el software Pull-Planner representan a muchos fabricantes y productos dentro de su clasificaci\u00f3n. Es importante saber que la mayor\u00eda de los datos de la tabla de fricci\u00f3n son promedios, y la variaci\u00f3n debe tenerse en cuenta cuando se utilizan los datos. Aunque existe una variaci\u00f3n entre los materiales de la cubierta del conducto y el cable, la lubricaci\u00f3n del cable es el mayor factor diferenciador, como se mostrar\u00e1 en la siguiente parte de este art\u00edculo.<\/p>\n<h2><strong>Resultados generales de la tabla de fricci\u00f3n<\/strong><\/h2>\n<p>El an\u00e1lisis y la presentaci\u00f3n de todas las conclusiones obtenidas de la tabla de fricci\u00f3n exceden el alcance de este art\u00edculo. Sin embargo, algunos hallazgos generalizados se destacan a continuaci\u00f3n.<\/p>\n<table style=\"width: 100%; border: 3px solid #273A80; background-color: #69c3e8; margin: 15px 0px 15px 0px;\">\n<tbody>\n<tr>\n<td style=\"padding: 20px; text-align: center;\"><a href=\"https:\/\/www.polywater.com\/es\/knowledge-hub\/la-mesa-de-friccion-polywater-perspectivas-personales\/\"><strong>Contenido relacionado: <\/strong>La mesa de fricci\u00f3n Polywater\u00ae: Perspectivas personales<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong>Efectos de la cubierta del cables<\/strong><\/h2>\n<p>El Gr\u00e1fico 3 muestra los coeficientes de fricci\u00f3n promedio para varias cubiertas en conductos de PVC, tanto lubricadas como no lubricadas.<\/p>\n<p>Los datos muestran la importancia de los lubricantes de alto rendimiento. Si bien los valores de coeficiente de fricci\u00f3n sin lubricaci\u00f3n var\u00edan entre 0,43 y 0,69, Polywater LZ es efectivo en una amplia gama de tipos de cubiertas. Los coeficientes de fricci\u00f3n m\u00e1s bajos que se pueden obtener con Polywater LZ producen tendidos de tensi\u00f3n m\u00e1s baja que, a su vez, permiten tramos de conducto m\u00e1s largos.<\/p>\n<p>Tenga en cuenta que la fricci\u00f3n sin lubricaci\u00f3n y la fricci\u00f3n con lubricaci\u00f3n var\u00edan seg\u00fan la cubierta. Si bien el lubricante de alto rendimiento Polywater LZ es un ecualizador, todav\u00eda existe un intervalo de fricci\u00f3n con lubricaci\u00f3n (entre 0,06 y 0,11) entre estas cubiertas.<\/p>\n<p><strong>Gr\u00e1fico 3<br \/>\n<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-21560\" src=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2023\/05\/Grafico-3-1.png\" alt=\"Un gr\u00e1fico que muestra los efectos de la chaqueta del cable cuando est\u00e1 lubricado y no lubricado\" width=\"700\" height=\"433\" srcset=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2023\/05\/Grafico-3-1.png 700w, https:\/\/www.polywater.com\/wp-content\/uploads\/2023\/05\/Grafico-3-1-300x186.png 300w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/p>\n<h2><strong>Efectos del conducto<\/strong><\/h2>\n<p>El Gr\u00e1fico 4 muestra los coeficientes de fricci\u00f3n promedio para la cubierta de PVC en varios tipos de conductos, nuevamente tanto lubricados como no lubricados.<\/p>\n<p>Como se esperaba, la fricci\u00f3n sin lubricaci\u00f3n es varias veces mayor que con lubricaci\u00f3n (entre 0,42 y 0,67). Tambi\u00e9n tenga en cuenta que existe una peque\u00f1a diferencia en la fricci\u00f3n con lubricaci\u00f3n seg\u00fan el tipo de conducto (en este caso, entre 0,11 y 0,13).<\/p>\n<p><strong>Gr\u00e1fico 4<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-11890\" src=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-4.png\" alt=\"Grafico 4\" width=\"700\" height=\"439\" srcset=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-4.png 1732w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-4-300x188.png 300w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-4-1024x641.png 1024w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-4-768x481.png 768w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-4-1536x962.png 1536w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/p>\n<h2><strong>Efectos del lubricante<\/strong><\/h2>\n<p>El Gr\u00e1fico 5 muestra los coeficientes de fricci\u00f3n promedios para la cubierta de PVC en un conducto de acero r\u00edgido y la cubierta de LLDPE en un conducto de PVC con diferentes lubricantes a comercializar para tendidos. Todos los lubricantes reducen la fricci\u00f3n y muestran grandes diferencias de coeficiente de fricci\u00f3n en comparaci\u00f3n con los cables sin lubricaci\u00f3n. El rendimiento del lubricante tambi\u00e9n depende de los materiales y la combinaci\u00f3n de superficies. El lubricante 3 muestra la mayor reducci\u00f3n de fricci\u00f3n para la cubierta de LLDPE con un conducto de PVC, pero no funciona tan bien en la cubierta de PVC con conducto de acero r\u00edgido.<\/p>\n<p><strong>Graph 5<\/strong><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-11894\" src=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-5.png\" alt=\"Grafico 5\" width=\"700\" height=\"420\" srcset=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-5.png 1732w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-5-300x180.png 300w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-5-1024x615.png 1024w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-5-768x461.png 768w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/08\/Grafico-5-1536x922.png 1536w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/p>\n<h2><strong>Limitaciones de la tabla de fricci\u00f3n de Polywater<\/strong><\/h2>\n<p>Si bien la tabla de fricci\u00f3n obtenida con el dispositivo, ha proporcionado una gran informaci\u00f3n sobre las variables que afectan a la fricci\u00f3n y la tensi\u00f3n, existen algunas limitaciones con respecto a lo que se puede probar en el dispositivo. A continuaci\u00f3n, se detallan algunas de sus limitaciones:<\/p>\n<p>1. La tabla de fricci\u00f3n representa una condici\u00f3n bien lubricada. Los aspectos como las propiedades de transporte del lubricante no se pueden medir en la m\u00e1quina.<\/p>\n<p>2. El dispositivo solo funciona con un solo cable, por lo que no se pueden estudiar variables como configuraciones del cables o cables de varios tama\u00f1os. Hemos realizado estudios sobre interferencias de cables y rellenos de cable en otros dispositivos de medici\u00f3n de la fricci\u00f3n de cables.<\/p>\n<p>3. Ciertas condiciones, como los tendidos a trav\u00e9s de conductos llenos de agua, pueden estudiarse a trav\u00e9s de tendidos repetitivos y mediciones comparativas de fricci\u00f3n. Si bien estos estudios son complejos, hemos realizado estudios especializados, generalmente con otros dispositivos de medici\u00f3n.<\/p>\n<p>4. Los cables peque\u00f1os y flexibles tienden a \u00abagruparse\u00bb y no ofrecen buenos resultados en el dispositivo.<\/p>\n<p>5. Si bien la tabla de fricci\u00f3n se puede aplicar en varias condiciones ambientales, su uso en lugares c\u00e1lidos o fr\u00edos no es pr\u00e1ctico, por lo que los datos representan las temperaturas de laboratorio t\u00edpicas de entre 68 \u00b0F y 72 \u00b0F (entre 20 \u00b0C y 22 \u00b0C).<\/p>\n<p>6. Si bien la presi\u00f3n normal en la tabla de fricci\u00f3n se puede ajustar, una gran mayor\u00eda de los datos hist\u00f3ricos se han obtenido con una presi\u00f3n normal en el intervalo de las 100 lbs (45,4 kg) (445 N). Si bien la variaci\u00f3n de fricci\u00f3n con presi\u00f3n normal puede estudiarse en el dispositivo, el uso de presiones normales bajas aumenta significativamente la variaci\u00f3n de la medici\u00f3n. Por lo tanto, se han estudiado los efectos de la presi\u00f3n normal sobre la fricci\u00f3n utilizando otros m\u00e9todos.<\/p>\n<table style=\"width: 100%; border: 3px solid #273A80; background-color: #69c3e8; margin: 15px 0px 15px 0px;\">\n<tbody>\n<tr>\n<td style=\"padding: 20px; text-align: center;\"><a href=\"https:\/\/www.polywater.com\/es\/knowledge-hub\/preguntas-frecuentes-tirado-de-cables-lubricacion-y-tension\/\"><strong>Contenido relacionado: <\/strong>Preguntas frecuentes: Tirado de cables, lubricaci\u00f3n y tensi\u00f3n<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><strong>Resumen<\/strong><\/h2>\n<p>La tabla de fricci\u00f3n de Polywater ofrece un m\u00e9todo conveniente y efectivo para medir la fricci\u00f3n. Hemos aprendido mucho sobre el dispositivo, incluida una base de medici\u00f3n para distancias de tracci\u00f3n ampliadas y tensiones m\u00e1s bajas gracias a los lubricantes para tendidos de Polywater. Los datos derivados de la tabla de fricci\u00f3n pueden ayudar a planificar y optimizar la instalaci\u00f3n de cables en conductos.<\/p>\n<h2>\u00bfPreguntas?<\/h2>\n<p><button class=\"button button--primary\" data-micromodal-trigger=\"polywater-modal--email-us-form\"> Env\u00edenos un correo electr\u00f3nico <\/button><\/p>\n<div class=\"modal micromodal-slide\" id=\"polywater-modal--email-us-form\" aria-hidden=\"true\"><div class=\"modal__overlay\" tabindex=\"-1\" data-micromodal-close><div class=\"modal__container\" role=\"dialog\" aria-modal=\"true\" aria-labelledby=\"polywater-modal--email-us-form-title\"><header class=\"modal__header\"><h2 id=\"polywater-modal--email-us-form-title\">Env\u00edenos un correo electr\u00f3nico<\/h2><button class=\"button--secondary modal__close\" aria-label=\"Cerrar modal\" data-micromodal-close><\/button><\/header><div id=\"polywater-modal--email-us-form-content\"><!-- [if lte IE 8]>\r\n<script charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"><\/script>\r\n<![endif]-->\r\n<script charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"><\/script>\r\n<script>\r\nhbspt.forms.create({\r\n  region: \"na1\",\r\n  portalId: \"6060295\",\r\n  formId: \"adf966af-6bc3-4520-9303-b49009f98e07\",\r\n  onFormReady: function (a) {\r\n    a.on('change', function(){\r\n      var zip = a.find('input[name=\"zip\"]');\r\n      if( zip ) {\r\n        if( zip.val() && zip.val().length > 4 ) {\r\n          var url = \"https:\/\/api.zippopotam.us\/us\/\" + zip.val();\r\n          var client = new XMLHttpRequest();\r\n          client.open(\"GET\", url, true);\r\n          client.onreadystatechange = function() {\r\n            if(client.readyState == 4) {\r\n              var resp = JSON.parse(client.responseText);\r\n              var city = resp.places[0]['place name'];\r\n              var state = resp.places[0]['state'];\r\n              a.find('input[name=\"city\"]').val(city);\r\n              a.find('input[name=\"state\"]').val(state);\r\n            };\r\n          };\r\n          client.send();\r\n        }\r\n      }\r\n    });\r\n  },\r\n});\r\n<\/script><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Medici\u00f3n de la fricci\u00f3n en la tabla de fricci\u00f3n de Polywater Polywater\u00ae ha medido el coeficiente de fricci\u00f3n de miles&#8230;<\/p>\n","protected":false},"author":21,"featured_media":11838,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[3056,3050,3052,3054,3060,3062],"tags":[1042,1043,2628,3406,3407],"industry-type":[2980,2981],"writer":[],"class_list":["post-11872","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cableado-subterraneo","category-instalacion-de-cable-en-conducto","category-tirado-de-cables","category-medicion-de-la-friccion","category-tipo-de-contenido","category-resumen-tecnico","tag-medicion-de-la-friccion","tag-coeficiente-de-friccion","tag-reibungstabelle-es","tag-friction-table-es","tag-coefficient-of-friction-es","industry-type-telecommunications","industry-type-electrical-infrastructure"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Medici\u00f3n de la fricci\u00f3n en la tabla de fricci\u00f3n de Polywater - Polywater<\/title>\n<meta name=\"description\" content=\"Descubra c\u00f3mo medimos la fricci\u00f3n con el dispositivo de mesa de fricci\u00f3n de Polywater para desarrollar informaci\u00f3n confiable sobre el coeficiente de fricci\u00f3n.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.polywater.com\/es\/knowledge-hub\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Medici\u00f3n de la fricci\u00f3n en la tabla de fricci\u00f3n de Polywater - Polywater\" \/>\n<meta property=\"og:description\" content=\"Descubra c\u00f3mo medimos la fricci\u00f3n con el dispositivo de mesa de fricci\u00f3n de Polywater para desarrollar informaci\u00f3n confiable sobre el coeficiente de fricci\u00f3n.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.polywater.com\/es\/knowledge-hub\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\/\" \/>\n<meta property=\"og:site_name\" content=\"Polywater\" \/>\n<meta property=\"article:published_time\" content=\"2021-08-20T16:49:05+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-12-01T20:50:19+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2020\/09\/Friction-Table-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1442\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Polywater\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Polywater\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/knowledge-hub\\\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/knowledge-hub\\\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\\\/\"},\"author\":{\"name\":\"Polywater\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/#\\\/schema\\\/person\\\/9e74a76ac184ba72afd5c4ef6d05e665\"},\"headline\":\"Medici\u00f3n de la fricci\u00f3n en la tabla de fricci\u00f3n de Polywater\",\"datePublished\":\"2021-08-20T16:49:05+00:00\",\"dateModified\":\"2023-12-01T20:50:19+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/knowledge-hub\\\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\\\/\"},\"wordCount\":1735,\"image\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/knowledge-hub\\\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.polywater.com\\\/wp-content\\\/uploads\\\/2020\\\/09\\\/Friction-Table-scaled.jpg\",\"keywords\":[\"medici\u00f3n de la fricci\u00f3n\",\"coeficiente de fricci\u00f3n\",\"Reibungstabelle\",\"friction table\",\"coefficient of friction\"],\"articleSection\":[\"Cableado subterr\u00e1neo\",\"Instalaci\u00f3n de cable en conducto\",\"Tirado de cables\",\"Medici\u00f3n de la fricci\u00f3n\",\"Tipo de contenido\",\"Resumen t\u00e9cnico\"],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/knowledge-hub\\\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\\\/\",\"url\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/knowledge-hub\\\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\\\/\",\"name\":\"Medici\u00f3n de la fricci\u00f3n en la tabla de fricci\u00f3n de Polywater - Polywater\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/knowledge-hub\\\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/knowledge-hub\\\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.polywater.com\\\/wp-content\\\/uploads\\\/2020\\\/09\\\/Friction-Table-scaled.jpg\",\"datePublished\":\"2021-08-20T16:49:05+00:00\",\"dateModified\":\"2023-12-01T20:50:19+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/#\\\/schema\\\/person\\\/9e74a76ac184ba72afd5c4ef6d05e665\"},\"description\":\"Descubra c\u00f3mo medimos la fricci\u00f3n con el dispositivo de mesa de fricci\u00f3n de Polywater para desarrollar informaci\u00f3n confiable sobre el coeficiente de fricci\u00f3n.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/knowledge-hub\\\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.polywater.com\\\/es\\\/knowledge-hub\\\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/knowledge-hub\\\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.polywater.com\\\/wp-content\\\/uploads\\\/2020\\\/09\\\/Friction-Table-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/www.polywater.com\\\/wp-content\\\/uploads\\\/2020\\\/09\\\/Friction-Table-scaled.jpg\",\"width\":2560,\"height\":1442,\"caption\":\"Mesa de fricci\u00f3n de Polywater y su equipamiento\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/knowledge-hub\\\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Medici\u00f3n de la fricci\u00f3n en la tabla de fricci\u00f3n de Polywater\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/#website\",\"url\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/\",\"name\":\"Polywater\",\"description\":\"Solutions at work.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/#\\\/schema\\\/person\\\/9e74a76ac184ba72afd5c4ef6d05e665\",\"name\":\"Polywater\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/72d4c760a3db080168572e040ed2bb5d184adda6d6520350f107ff55b34aa9bf?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/72d4c760a3db080168572e040ed2bb5d184adda6d6520350f107ff55b34aa9bf?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/72d4c760a3db080168572e040ed2bb5d184adda6d6520350f107ff55b34aa9bf?s=96&d=mm&r=g\",\"caption\":\"Polywater\"},\"url\":\"https:\\\/\\\/www.polywater.com\\\/es\\\/knowledge-hub\\\/author\\\/polywater\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Medici\u00f3n de la fricci\u00f3n en la tabla de fricci\u00f3n de Polywater - Polywater","description":"Descubra c\u00f3mo medimos la fricci\u00f3n con el dispositivo de mesa de fricci\u00f3n de Polywater para desarrollar informaci\u00f3n confiable sobre el coeficiente de fricci\u00f3n.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.polywater.com\/es\/knowledge-hub\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\/","og_locale":"es_ES","og_type":"article","og_title":"Medici\u00f3n de la fricci\u00f3n en la tabla de fricci\u00f3n de Polywater - Polywater","og_description":"Descubra c\u00f3mo medimos la fricci\u00f3n con el dispositivo de mesa de fricci\u00f3n de Polywater para desarrollar informaci\u00f3n confiable sobre el coeficiente de fricci\u00f3n.","og_url":"https:\/\/www.polywater.com\/es\/knowledge-hub\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\/","og_site_name":"Polywater","article_published_time":"2021-08-20T16:49:05+00:00","article_modified_time":"2023-12-01T20:50:19+00:00","og_image":[{"width":2560,"height":1442,"url":"https:\/\/www.polywater.com\/wp-content\/uploads\/2020\/09\/Friction-Table-scaled.jpg","type":"image\/jpeg"}],"author":"Polywater","twitter_card":"summary_large_image","twitter_misc":{"Escrito por":"Polywater","Tiempo de lectura":"9 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.polywater.com\/es\/knowledge-hub\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\/#article","isPartOf":{"@id":"https:\/\/www.polywater.com\/es\/knowledge-hub\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\/"},"author":{"name":"Polywater","@id":"https:\/\/www.polywater.com\/es\/#\/schema\/person\/9e74a76ac184ba72afd5c4ef6d05e665"},"headline":"Medici\u00f3n de la fricci\u00f3n en la tabla de fricci\u00f3n de Polywater","datePublished":"2021-08-20T16:49:05+00:00","dateModified":"2023-12-01T20:50:19+00:00","mainEntityOfPage":{"@id":"https:\/\/www.polywater.com\/es\/knowledge-hub\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\/"},"wordCount":1735,"image":{"@id":"https:\/\/www.polywater.com\/es\/knowledge-hub\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\/#primaryimage"},"thumbnailUrl":"https:\/\/www.polywater.com\/wp-content\/uploads\/2020\/09\/Friction-Table-scaled.jpg","keywords":["medici\u00f3n de la fricci\u00f3n","coeficiente de fricci\u00f3n","Reibungstabelle","friction table","coefficient of friction"],"articleSection":["Cableado subterr\u00e1neo","Instalaci\u00f3n de cable en conducto","Tirado de cables","Medici\u00f3n de la fricci\u00f3n","Tipo de contenido","Resumen t\u00e9cnico"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/www.polywater.com\/es\/knowledge-hub\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\/","url":"https:\/\/www.polywater.com\/es\/knowledge-hub\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\/","name":"Medici\u00f3n de la fricci\u00f3n en la tabla de fricci\u00f3n de Polywater - Polywater","isPartOf":{"@id":"https:\/\/www.polywater.com\/es\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.polywater.com\/es\/knowledge-hub\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\/#primaryimage"},"image":{"@id":"https:\/\/www.polywater.com\/es\/knowledge-hub\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\/#primaryimage"},"thumbnailUrl":"https:\/\/www.polywater.com\/wp-content\/uploads\/2020\/09\/Friction-Table-scaled.jpg","datePublished":"2021-08-20T16:49:05+00:00","dateModified":"2023-12-01T20:50:19+00:00","author":{"@id":"https:\/\/www.polywater.com\/es\/#\/schema\/person\/9e74a76ac184ba72afd5c4ef6d05e665"},"description":"Descubra c\u00f3mo medimos la fricci\u00f3n con el dispositivo de mesa de fricci\u00f3n de Polywater para desarrollar informaci\u00f3n confiable sobre el coeficiente de fricci\u00f3n.","breadcrumb":{"@id":"https:\/\/www.polywater.com\/es\/knowledge-hub\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.polywater.com\/es\/knowledge-hub\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.polywater.com\/es\/knowledge-hub\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\/#primaryimage","url":"https:\/\/www.polywater.com\/wp-content\/uploads\/2020\/09\/Friction-Table-scaled.jpg","contentUrl":"https:\/\/www.polywater.com\/wp-content\/uploads\/2020\/09\/Friction-Table-scaled.jpg","width":2560,"height":1442,"caption":"Mesa de fricci\u00f3n de Polywater y su equipamiento"},{"@type":"BreadcrumbList","@id":"https:\/\/www.polywater.com\/es\/knowledge-hub\/medicion-de-la-friccion-en-la-tabla-de-friccion-de-polywater\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.polywater.com\/es\/"},{"@type":"ListItem","position":2,"name":"Medici\u00f3n de la fricci\u00f3n en la tabla de fricci\u00f3n de Polywater"}]},{"@type":"WebSite","@id":"https:\/\/www.polywater.com\/es\/#website","url":"https:\/\/www.polywater.com\/es\/","name":"Polywater","description":"Solutions at work.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.polywater.com\/es\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Person","@id":"https:\/\/www.polywater.com\/es\/#\/schema\/person\/9e74a76ac184ba72afd5c4ef6d05e665","name":"Polywater","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/secure.gravatar.com\/avatar\/72d4c760a3db080168572e040ed2bb5d184adda6d6520350f107ff55b34aa9bf?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/72d4c760a3db080168572e040ed2bb5d184adda6d6520350f107ff55b34aa9bf?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/72d4c760a3db080168572e040ed2bb5d184adda6d6520350f107ff55b34aa9bf?s=96&d=mm&r=g","caption":"Polywater"},"url":"https:\/\/www.polywater.com\/es\/knowledge-hub\/author\/polywater\/"}]}},"_links":{"self":[{"href":"https:\/\/www.polywater.com\/es\/wp-json\/wp\/v2\/posts\/11872","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.polywater.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.polywater.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.polywater.com\/es\/wp-json\/wp\/v2\/users\/21"}],"replies":[{"embeddable":true,"href":"https:\/\/www.polywater.com\/es\/wp-json\/wp\/v2\/comments?post=11872"}],"version-history":[{"count":0,"href":"https:\/\/www.polywater.com\/es\/wp-json\/wp\/v2\/posts\/11872\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.polywater.com\/es\/wp-json\/wp\/v2\/media\/11838"}],"wp:attachment":[{"href":"https:\/\/www.polywater.com\/es\/wp-json\/wp\/v2\/media?parent=11872"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.polywater.com\/es\/wp-json\/wp\/v2\/categories?post=11872"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.polywater.com\/es\/wp-json\/wp\/v2\/tags?post=11872"},{"taxonomy":"industry-type","embeddable":true,"href":"https:\/\/www.polywater.com\/es\/wp-json\/wp\/v2\/industry-type?post=11872"},{"taxonomy":"writer","embeddable":true,"href":"https:\/\/www.polywater.com\/es\/wp-json\/wp\/v2\/writer?post=11872"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}