{"id":13523,"date":"2022-05-29T23:09:32","date_gmt":"2022-05-30T04:09:32","guid":{"rendered":"https:\/\/www.polywater.com\/?p=13523"},"modified":"2025-05-15T13:34:53","modified_gmt":"2025-05-15T18:34:53","slug":"model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2","status":"publish","type":"post","link":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/","title":{"rendered":"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 2"},"content":{"rendered":"<div id=\"vyLightbox\"><\/div>\n<p>In a previous <a href=\"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/\">article<\/a>, we modeled the reel-memory displacement in continuous fiber optic duct as shown in Figure 1.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-16448 size-large\" src=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-1-no-title-1-1024x352.png\" alt=\"Figure 1 - Model of Regular Duct Displacement\" width=\"1024\" height=\"352\" srcset=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-1-no-title-1-1024x352.png 1024w, https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-1-no-title-1-300x103.png 300w, https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-1-no-title-1-768x264.png 768w, https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-1-no-title-1.png 1287w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p><b>FIGURE 1. Model of Regular Duct Displacement<\/b><\/p>\n<p>This model treats duct displacement as a &#8220;repeating wave\u201d running the length of the conduit. This wave is described by its &#8220;amplitude (A)&#8221;, the maximum displacement from a straight line, and its &#8220;period (P)&#8221;, the repeating distance from peak to peak.<\/p>\n<table style=\"width: 100%; border: 3px solid #273A80; background-color: #69c3e8; margin: 15px 0px 15px 0px;\">\n<tbody>\n<tr>\n<td style=\"padding: 20px; text-align: center;\"><a href=\"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-placement-factor-in-fiber-optic-cable-pulling-the-effect-of-cof-on-the-duct-displacement-model\/\"><strong>Related Content: <\/strong>Model and Analysis of Duct Placement Factor in Fiber Optic Cable Pulling \u2013 The effect of COF on the Duct Displacement Model<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>From the model, we can mathematically determine the total angle of bend per period P. The angle of bend per unit of length is more useful and can be calculated based on the repeating nature of the period. Table 1 shows a few calculations based on typical periods and amplitude data. A 12-inch amplitude might be an extreme for duct laid in an open trench and 1.5-inch typical for duct restricted inside an exterior hard-sided duct.<\/p>\n<p><b>TABLE 1. Effective Bend Introduced by Regular Duct Displacements<\/b><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-16440 size-large\" src=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Table-1-1-1024x344.png\" alt=\"TABLE 1. Effective Bend Introduced by Regular Duct Displacements\" width=\"1024\" height=\"344\" srcset=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Table-1-1-1024x344.png 1024w, https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Table-1-1-300x101.png 300w, https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Table-1-1-768x258.png 768w, https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Table-1-1-1536x516.png 1536w, https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Table-1-1.png 1615w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p>As we expect, Table 1 shows the higher the amplitude and\/or the shorter the period, the higher the effective bend per unit of length. The table shows effective bends that vary from 0.6 degree\/foot to as high as 15 degrees\/foot of duct (2 to 50 degrees\/meter). While this may not seem like much, it means hidden bend of 3,000 degrees to 75,000 degrees in 5,000 feet (1,500 m) of fiber optic pull!<\/p>\n<table style=\"width: 100%; border: 3px solid #273A80; background-color: #69c3e8; margin: 15px 0px 15px 0px;\">\n<tbody>\n<tr>\n<td style=\"padding: 20px; text-align: center;\"><a href=\"https:\/\/www.polywater.com\/en\/knowledge-hub\/measuring-cable-pulling-friction-with-a-reel-test\/\"><strong>Related Content: <\/strong>Measuring Cable Pulling Friction with a Reel Test<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Figure 2 below graphs effective bend against displacement amplitude at three different periods. We see that even at the largest magnitude period of 30 feet, displacements of 0.5-foot (6 inches) result in greater than one degree of bend per foot. This considerable amount of bend will directly impact pull tension. The pulling equation for a bend indicates the less the bend, the lower the tension in a pull. Can we quantify this to determine allowable bend?<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-16452 size-large\" src=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-2-1024x759.png\" alt=\"FIGURE 2. Effective Bend Resulting from Regular Duct Displacement\" width=\"1024\" height=\"759\" srcset=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-2-1024x759.png 1024w, https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-2-300x222.png 300w, https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-2-768x569.png 768w, https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-2-1536x1139.png 1536w, https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-2.png 1909w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p><b>FIGURE 2. Effective Bend Resulting from Regular Duct Displacement<\/b><\/p>\n<h2><b>Pulling tension estimates using the model<\/b><\/h2>\n<p>To use the equations to determine tension, we must input cable weight and friction data. Figure 3 below assumes a cable weight of 0.1 lb.\/ft, a friction coefficient of 0.10, and an initial incoming tension on the cable of 10 lbs. It plots estimated final pulling tension against effective bend for a 1,000-, 3,000-, and 5,000-foot pull.<\/p>\n<table style=\"width: 100%; border: 3px solid #273A80; background-color: #69c3e8; margin: 15px 0px 15px 0px;\">\n<tbody>\n<tr>\n<td style=\"padding: 20px; text-align: center;\"><a href=\"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/\"><strong>Related Content: <\/strong>Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 1<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The graph in Figure 3 shows that to keep tensions under 600 lbs. and to pull longer distances (3,000 feet plus), it is necessary to keep effective bend under 0.5 degrees per foot. This means a maximum displacement amplitude of less than 1 inch per 20-foot period.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-16456 size-large\" src=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-3-1024x873.png\" alt=\"Figure 3. Predicted Tension vs Effective Bend\" width=\"1024\" height=\"873\" srcset=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-3-1024x873.png 1024w, https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-3-300x256.png 300w, https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-3-768x655.png 768w, https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-3.png 1233w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p><b>FIGURE 3. Predicted Tension vs Effective Bend<\/b><\/p>\n<h2><b>Field pulling experience<\/b><\/h2>\n<p>Figure 3 agrees at least anecdotally with field observations. It is usually not possible to pull cable even a thousand feet into an innerduct laid in an open trench and then covered. Even with a low COF, the pull tension exceeds 600 lbs within 1,000 feet of a pull that has 1.94 degrees of effective bend per foot. The trenched duct (A=12 inches, P=20 feet) modeled in Table 1 has twice an effective bend, 4.4 degrees\/ft. But, with the lower displacements possible with pre-ripped plowing or innerduct in an outer conduit in under-bridge installations, pulls of 3,000 to 5,000 feet (1,500 m) have been done at tensions less than 600 lbs.<\/p>\n<p>A potential use for this model is to use it \u201cin reverse\u201d to evaluate duct placement methods. Such studies have shown the importance of duct wall thickness in plowed and bored duct, the value of pre-ripping the soil in plowing, and more. Once we know the pulling tension for any given pull, we can determine the effective bend, and then experiment with the variables that may lower it.<\/p>\n<h2>Have any questions?<\/h2>\n<p><button class=\"button button--primary\" data-micromodal-trigger=\"polywater-modal--email-us-form\">Email Us <\/button><\/p>\n<div class=\"modal micromodal-slide\" id=\"polywater-modal--email-us-form\" aria-hidden=\"true\"><div class=\"modal__overlay\" tabindex=\"-1\" data-micromodal-close><div class=\"modal__container\" role=\"dialog\" aria-modal=\"true\" aria-labelledby=\"polywater-modal--email-us-form-title\"><header class=\"modal__header\"><h2 id=\"polywater-modal--email-us-form-title\">Email Us Form<\/h2><button class=\"button--secondary modal__close\" aria-label=\"Close modal\" data-micromodal-close><\/button><\/header><div id=\"polywater-modal--email-us-form-content\"><!-- [if lte IE 8]>\r\n<script charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"><\/script>\r\n<![endif]-->\r\n<script charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"><\/script>\r\n<script>\r\nhbspt.forms.create({\r\n  region: \"na1\",\r\n  portalId: \"6060295\",\r\n  formId: \"7658eeb9-0cf9-469d-a7f1-0f033127bb9d\",\r\n  onFormReady: function (a) {\r\n    a.on('change', function(){\r\n      var zip = a.find('input[name=\"zip\"]');\r\n      if( zip ) {\r\n        if( zip.val() && zip.val().length > 4 ) {\r\n          var url = \"https:\/\/api.zippopotam.us\/us\/\" + zip.val();\r\n          var client = new XMLHttpRequest();\r\n          client.open(\"GET\", url, true);\r\n          client.onreadystatechange = function() {\r\n            if(client.readyState == 4) {\r\n              var resp = JSON.parse(client.responseText);\r\n              var city = resp.places[0]['place name'];\r\n              var state = resp.places[0]['state'];\r\n              a.find('input[name=\"city\"]').val(city);\r\n              a.find('input[name=\"state\"]').val(state);\r\n            };\r\n          };\r\n          client.send();\r\n        }\r\n      }\r\n    });\r\n  },\r\n});\r\n<\/script><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>In a previous article, we modeled the reel-memory displacement in continuous fiber optic duct as shown in Figure 1. FIGURE&#8230;<\/p>\n","protected":false},"author":7,"featured_media":13510,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[2992,2982,2984,3013,2987,3004,3010],"tags":[],"industry-type":[2980],"writer":[2704,2945],"class_list":["post-13523","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-underground-cabling","category-cable-in-duct-installation","category-cable-pulling","category-cable-blowing","category-friction-management","category-content-type","category-technical-paper","industry-type-telecommunications","writer-sheri-dahlke","writer-john-fee-2"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 2 - Polywater<\/title>\n<meta name=\"description\" content=\"Because conduit is pulled from a reel when being installed underground, it\u2019s important to recognize that there may be undulations that create low-angle bends.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 2 - Polywater\" \/>\n<meta property=\"og:description\" content=\"Because conduit is pulled from a reel when being installed underground, it\u2019s important to recognize that there may be undulations that create low-angle bends.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/\" \/>\n<meta property=\"og:site_name\" content=\"Polywater\" \/>\n<meta property=\"article:published_time\" content=\"2022-05-30T04:09:32+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-15T18:34:53+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/12\/Figure-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"618\" \/>\n\t<meta property=\"og:image:height\" content=\"256\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Rick Schmolke\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Rick Schmolke\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\\\/\"},\"author\":{\"name\":\"Rick Schmolke\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/#\\\/schema\\\/person\\\/946caa235fcb434befeba8ff52150eb5\"},\"headline\":\"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 2\",\"datePublished\":\"2022-05-30T04:09:32+00:00\",\"dateModified\":\"2025-05-15T18:34:53+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\\\/\"},\"wordCount\":643,\"image\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.polywater.com\\\/wp-content\\\/uploads\\\/2021\\\/12\\\/Figure-1.jpg\",\"articleSection\":[\"Underground Cabling\",\"Cable-in-duct Installation\",\"Cable Pulling\",\"Cable Blowing\",\"Friction Management\",\"Content Type\",\"Technical Paper\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\\\/\",\"url\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\\\/\",\"name\":\"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 2 - Polywater\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.polywater.com\\\/wp-content\\\/uploads\\\/2021\\\/12\\\/Figure-1.jpg\",\"datePublished\":\"2022-05-30T04:09:32+00:00\",\"dateModified\":\"2025-05-15T18:34:53+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/#\\\/schema\\\/person\\\/946caa235fcb434befeba8ff52150eb5\"},\"description\":\"Because conduit is pulled from a reel when being installed underground, it\u2019s important to recognize that there may be undulations that create low-angle bends.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.polywater.com\\\/wp-content\\\/uploads\\\/2021\\\/12\\\/Figure-1.jpg\",\"contentUrl\":\"https:\\\/\\\/www.polywater.com\\\/wp-content\\\/uploads\\\/2021\\\/12\\\/Figure-1.jpg\",\"width\":618,\"height\":256,\"caption\":\"Figure 1 - Model of Regular Duct Displacement\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 2\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/\",\"name\":\"Polywater\",\"description\":\"Solutions at work.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/#\\\/schema\\\/person\\\/946caa235fcb434befeba8ff52150eb5\",\"name\":\"Rick Schmolke\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/53c2625a8c8a729cfdb238a18af45351278a1de8d575eb0c32622108d1a17c2b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/53c2625a8c8a729cfdb238a18af45351278a1de8d575eb0c32622108d1a17c2b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/53c2625a8c8a729cfdb238a18af45351278a1de8d575eb0c32622108d1a17c2b?s=96&d=mm&r=g\",\"caption\":\"Rick Schmolke\"},\"url\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/author\\\/rick\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 2 - Polywater","description":"Because conduit is pulled from a reel when being installed underground, it\u2019s important to recognize that there may be undulations that create low-angle bends.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/","og_locale":"en_US","og_type":"article","og_title":"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 2 - Polywater","og_description":"Because conduit is pulled from a reel when being installed underground, it\u2019s important to recognize that there may be undulations that create low-angle bends.","og_url":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/","og_site_name":"Polywater","article_published_time":"2022-05-30T04:09:32+00:00","article_modified_time":"2025-05-15T18:34:53+00:00","og_image":[{"width":618,"height":256,"url":"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/12\/Figure-1.jpg","type":"image\/jpeg"}],"author":"Rick Schmolke","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Rick Schmolke","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/#article","isPartOf":{"@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/"},"author":{"name":"Rick Schmolke","@id":"https:\/\/www.polywater.com\/en\/#\/schema\/person\/946caa235fcb434befeba8ff52150eb5"},"headline":"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 2","datePublished":"2022-05-30T04:09:32+00:00","dateModified":"2025-05-15T18:34:53+00:00","mainEntityOfPage":{"@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/"},"wordCount":643,"image":{"@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/#primaryimage"},"thumbnailUrl":"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/12\/Figure-1.jpg","articleSection":["Underground Cabling","Cable-in-duct Installation","Cable Pulling","Cable Blowing","Friction Management","Content Type","Technical Paper"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/","url":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/","name":"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 2 - Polywater","isPartOf":{"@id":"https:\/\/www.polywater.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/#primaryimage"},"image":{"@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/#primaryimage"},"thumbnailUrl":"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/12\/Figure-1.jpg","datePublished":"2022-05-30T04:09:32+00:00","dateModified":"2025-05-15T18:34:53+00:00","author":{"@id":"https:\/\/www.polywater.com\/en\/#\/schema\/person\/946caa235fcb434befeba8ff52150eb5"},"description":"Because conduit is pulled from a reel when being installed underground, it\u2019s important to recognize that there may be undulations that create low-angle bends.","breadcrumb":{"@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/#primaryimage","url":"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/12\/Figure-1.jpg","contentUrl":"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/12\/Figure-1.jpg","width":618,"height":256,"caption":"Figure 1 - Model of Regular Duct Displacement"},{"@type":"BreadcrumbList","@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.polywater.com\/en\/"},{"@type":"ListItem","position":2,"name":"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 2"}]},{"@type":"WebSite","@id":"https:\/\/www.polywater.com\/en\/#website","url":"https:\/\/www.polywater.com\/en\/","name":"Polywater","description":"Solutions at work.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.polywater.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.polywater.com\/en\/#\/schema\/person\/946caa235fcb434befeba8ff52150eb5","name":"Rick Schmolke","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/53c2625a8c8a729cfdb238a18af45351278a1de8d575eb0c32622108d1a17c2b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/53c2625a8c8a729cfdb238a18af45351278a1de8d575eb0c32622108d1a17c2b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/53c2625a8c8a729cfdb238a18af45351278a1de8d575eb0c32622108d1a17c2b?s=96&d=mm&r=g","caption":"Rick Schmolke"},"url":"https:\/\/www.polywater.com\/en\/knowledge-hub\/author\/rick\/"}]}},"_links":{"self":[{"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/posts\/13523","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/comments?post=13523"}],"version-history":[{"count":0,"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/posts\/13523\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/media\/13510"}],"wp:attachment":[{"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/media?parent=13523"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/categories?post=13523"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/tags?post=13523"},{"taxonomy":"industry-type","embeddable":true,"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/industry-type?post=13523"},{"taxonomy":"writer","embeddable":true,"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/writer?post=13523"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}