{"id":13501,"date":"2022-02-01T14:52:58","date_gmt":"2022-02-01T20:52:58","guid":{"rendered":"https:\/\/www.polywater.com\/?p=13501"},"modified":"2025-05-15T16:20:32","modified_gmt":"2025-05-15T21:20:32","slug":"model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1","status":"publish","type":"post","link":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/","title":{"rendered":"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 1"},"content":{"rendered":"<div id=\"vyLightbox\"><\/div>\n<h2><b>Why is duct displacement significant to underground installation of fiber?<\/b><\/h2>\n<p>Because conduit is pulled from a reel when being buried underground, it\u2019s important to recognize that there may be undulations that create low-angle bends. During installation, the conduit can appear like it\u2019s running straight, but when pulling cable long distances, slight bends in the conduit can add up and produce higher pull tensions.<\/p>\n<table style=\"width: 100%; border: 3px solid #273A80; background-color: #69c3e8; margin: 15px 0px 15px 0px;\">\n<tbody>\n<tr>\n<td style=\"padding: 20px; text-align: center;\"><a href=\"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/\" target=\"_blank\" rel=\"noopener\"><strong>Related Content: <\/strong>Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 2<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>What is different about fiber optic cable pulling?<\/b><\/h2>\n<p>When pulling underground fiber optic cable, we often want as long an uninterrupted span of the cable as we can get.\u00a0So, if the cable comes on a 10 km (32,800 ft) reel, we want a full, unbroken 10 km span to eliminate any splice-induced attenuation.<\/p>\n<p>To determine the pulling lengths that are possible, we can use the &#8220;cable pulling equations&#8221; to estimate cable pulling tension based on friction, cable weight, and conduit run details. Such estimates have shown good correlation with field-measured tension when heavy cable is pulled into hard-sided conduit, but the length of the runs is much shorter than we want for fiber.\u00a0Plus, fiber optic cable is much lighter weight than twisted pair copper cable.<\/p>\n<p>The equations predict that fiber can be pulled much longer distances than is possible today. Assuming a typical 600 lb. (2.7 kN) maximum tension, theory says it should be possible to pull fiber cable (with a typical weight of 100 lbs\/1,000 feet (150 kg\/km)) some 30,000 feet (9+ km).\u202f This estimate uses a friction coefficient of 0.2, and that is not unreasonable as much lower friction coefficients have been measured using Polywater\u2019s high-performance, fiber optic pulling lubricants.<\/p>\n<p>Real field experience shows more typical pulling distances of 1,500 to 2,000 feet (0.46 to 0.61 Km) to keep tensions under 600 lbs. (2.7 kN), even into a new, well-placed duct system.\u00a0Why do pulls of fiber optic cable show such poor correlation with calculations based on the theory?<\/p>\n<table style=\"width: 100%; border: 3px solid #273A80; background-color: #69c3e8; margin: 15px 0px 15px 0px;\">\n<tbody>\n<tr>\n<td style=\"padding: 20px; text-align: center;\"><a href=\"https:\/\/www.polywater.com\/en\/knowledge-hub\/measuring-cable-pulling-friction-with-a-reel-test\/\" target=\"_blank\" rel=\"noopener\"><strong>Related Content: <\/strong>Measuring Cable Pulling Friction with a Reel Test<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>The duct factor<\/b><\/h2>\n<p>Fiber optic cable is generally pulled into continuous, reeled, PE or flexible PVC duct. When this duct is pulled from the reel and trenched, plowed, pulled, or bored, it retains some reel memory that produces slight, but regular, displacements or undulations. While a run appears &#8220;straight&#8221;, the duct reel memory displacements behave like low-angle bends. With the long pulls typical of fiber optic, these bends add up, and produce higher tension than expected.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-13506 size-full\" src=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/12\/Duct-undulations.jpg\" alt=\"Laying a fiber optic cable for fast internet, Electricity and telephone cable along a new street. Cable Installation power lines at city street, industrial electricity and communication concept.\" width=\"700\" height=\"467\" srcset=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/12\/Duct-undulations.jpg 700w, https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/12\/Duct-undulations-300x200.jpg 300w\" sizes=\"auto, (max-width: 700px) 100vw, 700px\" \/><\/p>\n<p>To better understand this, let us look at the simplified form of a cable pulling bend equation.<\/p>\n<p>Conduit Bend\u202f\u202f\u202f\u202f\u202f\u202f\u202f\u202f\u202fT<sub>out<\/sub> = T<sub>in <\/sub>e<sup>\u03bc\u03f4<\/sup><br \/>\nWhere:<br \/>\nT<sub>out<\/sub> = Tension\u202fOut<br \/>\nT<sub>in<\/sub> = Tension\u202fin<br \/>\n\u03bc\u202f= Coefficient\u202fof Friction<br \/>\n\u03f4 = Angle\u202fof Bend\u202f(radians)<br \/>\ne = Naperian\u202fLog Base<\/p>\n<p>We see that if we double the bend angle, the multiplier squares, and 10 times the angle increases the multiplier to the tenth power. The angle is in an exponent.<\/p>\n<table style=\"width: 100%; border: 3px solid #273A80; background-color: #69c3e8; margin: 15px 0px 15px 0px;\">\n<tbody>\n<tr>\n<td style=\"padding: 20px; text-align: center;\"><a href=\"https:\/\/www.polywater.com\/en\/knowledge-hub\/planning-cabling-projects-improves-success-and-safety\/\" target=\"_blank\" rel=\"noopener\"><strong>Related Content: <\/strong>Planning Cabling Projects Improves Success and Safety<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><b>Modeling duct factor.<\/b><\/h2>\n<p>To quantify this in fiber optic pulling, we need to model the duct displacement, as shown in Figure 1.<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-16448 size-large\" src=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-1-no-title-1-1024x352.png\" alt=\"Figure 1 - Model of Regular Duct Displacement\" width=\"1024\" height=\"352\" srcset=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-1-no-title-1-1024x352.png 1024w, https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-1-no-title-1-300x103.png 300w, https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-1-no-title-1-768x264.png 768w, https:\/\/www.polywater.com\/wp-content\/uploads\/2022\/04\/Figure-1-no-title-1.png 1287w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/p>\n<p><b>Figure 1 \u2013 Model of Regular Duct Displacement<\/b><\/p>\n<p>This model treats the displacement as a &#8220;repeating wave&#8221; running the length of the conduit. This wave is described by its &#8220;amplitude (A)&#8221;, the maximum displacement from a straight line, and its &#8220;period (P)&#8221;, the repeating distance from peak to peak.\u00a0We might guess that P is related to the duct reel diameter and A to the method of duct installation.<\/p>\n<p>Field placements have shown several variables that affect the amplitude and period.\u00a0These include duct type, wall thickness, reel diameter, duct OD, and placement method. For reeled innerduct dropped into an open trench, a wave with an amplitude as high as 12 inches (300 mm) and a repeating period of 20 feet (3 m) has been observed.\u00a0 The same duct pulled into 4&#8243; (100 mm) Schedule 80 PVC might only have an amplitude of 0.75&#8243; (20 mm) every 20 feet (3 m). For the thick-wall ducts used for \u201cplowing\u201d and directional boring, the regular displacements cannot be easily observed but are known to depend on soil type and rockiness, and they can be measured using geolocation robots run through the duct.<\/p>\n<table style=\"width: 100%; border: 3px solid #273A80; background-color: #69c3e8; margin: 15px 0px 15px 0px;\">\n<tbody>\n<tr>\n<td style=\"padding: 20px; text-align: center;\"><a href=\"https:\/\/www.polywater.com\/en\/knowledge-hub\/coefficient-of-friction-in-cable-pulling-part-3\/\" target=\"_blank\" rel=\"noopener\"><strong>Related Content: <\/strong>Coefficient of Friction\u202fin Cable Pulling Tension from Conduit Bends<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>This model allows us to quantify the &#8220;bend&#8221; in a &#8220;straight&#8221; run based on the displacement amplitude and the repeating period, and then to use the pulling equations to determine the effect of that bend. The next issue will work that math and show the analysis.<\/p>\n<p>In <a href=\"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-2\/\">part two of this series<\/a>, we show how total angle of bend per period is related to effective bend per length of duct. This information can lead to improved tension prediction with real-world application.<\/p>\n<h2>Have any questions?<\/h2>\n<p><button class=\"button button--primary\" data-micromodal-trigger=\"polywater-modal--email-us-form\">Email Us <\/button><\/p>\n<div class=\"modal micromodal-slide\" id=\"polywater-modal--email-us-form\" aria-hidden=\"true\"><div class=\"modal__overlay\" tabindex=\"-1\" data-micromodal-close><div class=\"modal__container\" role=\"dialog\" aria-modal=\"true\" aria-labelledby=\"polywater-modal--email-us-form-title\"><header class=\"modal__header\"><h2 id=\"polywater-modal--email-us-form-title\">Email Us Form<\/h2><button class=\"button--secondary modal__close\" aria-label=\"Close modal\" data-micromodal-close><\/button><\/header><div id=\"polywater-modal--email-us-form-content\"><!-- [if lte IE 8]>\r\n<script charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2-legacy.js\"><\/script>\r\n<![endif]-->\r\n<script charset=\"utf-8\" type=\"text\/javascript\" src=\"\/\/js.hsforms.net\/forms\/v2.js\"><\/script>\r\n<script>\r\nhbspt.forms.create({\r\n  region: \"na1\",\r\n  portalId: \"6060295\",\r\n  formId: \"7658eeb9-0cf9-469d-a7f1-0f033127bb9d\",\r\n  onFormReady: function (a) {\r\n    a.on('change', function(){\r\n      var zip = a.find('input[name=\"zip\"]');\r\n      if( zip ) {\r\n        if( zip.val() && zip.val().length > 4 ) {\r\n          var url = \"https:\/\/api.zippopotam.us\/us\/\" + zip.val();\r\n          var client = new XMLHttpRequest();\r\n          client.open(\"GET\", url, true);\r\n          client.onreadystatechange = function() {\r\n            if(client.readyState == 4) {\r\n              var resp = JSON.parse(client.responseText);\r\n              var city = resp.places[0]['place name'];\r\n              var state = resp.places[0]['state'];\r\n              a.find('input[name=\"city\"]').val(city);\r\n              a.find('input[name=\"state\"]').val(state);\r\n            };\r\n          };\r\n          client.send();\r\n        }\r\n      }\r\n    });\r\n  },\r\n});\r\n<\/script><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Why is duct displacement significant to underground installation of fiber? Because conduit is pulled from a reel when being buried&#8230;<\/p>\n","protected":false},"author":22,"featured_media":13506,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_relevanssi_hide_post":"","_relevanssi_hide_content":"","_relevanssi_pin_for_all":"","_relevanssi_pin_keywords":"","_relevanssi_unpin_keywords":"","_relevanssi_related_keywords":"","_relevanssi_related_include_ids":"","_relevanssi_related_exclude_ids":"","_relevanssi_related_no_append":"","_relevanssi_related_not_related":"","_relevanssi_related_posts":"","_relevanssi_noindex_reason":"","footnotes":""},"categories":[2992,2982,2984,3013,2987,3004,3010],"tags":[],"industry-type":[2980],"writer":[],"class_list":["post-13501","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-underground-cabling","category-cable-in-duct-installation","category-cable-pulling","category-cable-blowing","category-friction-management","category-content-type","category-technical-paper","industry-type-telecommunications"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 1 - Polywater<\/title>\n<meta name=\"description\" content=\"Because fiber optic cable is pulled from a reel when being installed underground, it\u2019s important to recognize that there may be undulations...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 1 - Polywater\" \/>\n<meta property=\"og:description\" content=\"Because fiber optic cable is pulled from a reel when being installed underground, it\u2019s important to recognize that there may be undulations...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Polywater\" \/>\n<meta property=\"article:published_time\" content=\"2022-02-01T20:52:58+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-15T21:20:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/12\/Duct-undulations.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t<meta property=\"og:image:height\" content=\"467\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Sheri Dahlke\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Sheri Dahlke\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\\\/\"},\"author\":{\"name\":\"Sheri Dahlke\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/#\\\/schema\\\/person\\\/3734e7b75c8edb79b63ccf415c884f9c\"},\"headline\":\"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 1\",\"datePublished\":\"2022-02-01T20:52:58+00:00\",\"dateModified\":\"2025-05-15T21:20:32+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\\\/\"},\"wordCount\":792,\"image\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.polywater.com\\\/wp-content\\\/uploads\\\/2021\\\/12\\\/Duct-undulations.jpg\",\"articleSection\":[\"Underground Cabling\",\"Cable-in-duct Installation\",\"Cable Pulling\",\"Cable Blowing\",\"Friction Management\",\"Content Type\",\"Technical Paper\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\\\/\",\"url\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\\\/\",\"name\":\"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 1 - Polywater\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.polywater.com\\\/wp-content\\\/uploads\\\/2021\\\/12\\\/Duct-undulations.jpg\",\"datePublished\":\"2022-02-01T20:52:58+00:00\",\"dateModified\":\"2025-05-15T21:20:32+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/#\\\/schema\\\/person\\\/3734e7b75c8edb79b63ccf415c884f9c\"},\"description\":\"Because fiber optic cable is pulled from a reel when being installed underground, it\u2019s important to recognize that there may be undulations...\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.polywater.com\\\/wp-content\\\/uploads\\\/2021\\\/12\\\/Duct-undulations.jpg\",\"contentUrl\":\"https:\\\/\\\/www.polywater.com\\\/wp-content\\\/uploads\\\/2021\\\/12\\\/Duct-undulations.jpg\",\"width\":700,\"height\":467,\"caption\":\"Laying a fiber optic cable for fast internet, Electricity and telephone cable along a new street. Cable Installation power lines at city street, industrial electricity and communication concept.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/\",\"name\":\"Polywater\",\"description\":\"Solutions at work.\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/#\\\/schema\\\/person\\\/3734e7b75c8edb79b63ccf415c884f9c\",\"name\":\"Sheri Dahlke\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b3172121d8dd4a15b6c79ef31d9a1e2fa90f220dfe15563ddc1c5c81e2a7939f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b3172121d8dd4a15b6c79ef31d9a1e2fa90f220dfe15563ddc1c5c81e2a7939f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b3172121d8dd4a15b6c79ef31d9a1e2fa90f220dfe15563ddc1c5c81e2a7939f?s=96&d=mm&r=g\",\"caption\":\"Sheri Dahlke\"},\"url\":\"https:\\\/\\\/www.polywater.com\\\/en\\\/knowledge-hub\\\/author\\\/sheri-dahlke\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 1 - Polywater","description":"Because fiber optic cable is pulled from a reel when being installed underground, it\u2019s important to recognize that there may be undulations...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/","og_locale":"en_US","og_type":"article","og_title":"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 1 - Polywater","og_description":"Because fiber optic cable is pulled from a reel when being installed underground, it\u2019s important to recognize that there may be undulations...","og_url":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/","og_site_name":"Polywater","article_published_time":"2022-02-01T20:52:58+00:00","article_modified_time":"2025-05-15T21:20:32+00:00","og_image":[{"width":700,"height":467,"url":"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/12\/Duct-undulations.jpg","type":"image\/jpeg"}],"author":"Sheri Dahlke","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Sheri Dahlke","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/#article","isPartOf":{"@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/"},"author":{"name":"Sheri Dahlke","@id":"https:\/\/www.polywater.com\/en\/#\/schema\/person\/3734e7b75c8edb79b63ccf415c884f9c"},"headline":"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 1","datePublished":"2022-02-01T20:52:58+00:00","dateModified":"2025-05-15T21:20:32+00:00","mainEntityOfPage":{"@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/"},"wordCount":792,"image":{"@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/#primaryimage"},"thumbnailUrl":"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/12\/Duct-undulations.jpg","articleSection":["Underground Cabling","Cable-in-duct Installation","Cable Pulling","Cable Blowing","Friction Management","Content Type","Technical Paper"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/","url":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/","name":"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 1 - Polywater","isPartOf":{"@id":"https:\/\/www.polywater.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/#primaryimage"},"image":{"@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/#primaryimage"},"thumbnailUrl":"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/12\/Duct-undulations.jpg","datePublished":"2022-02-01T20:52:58+00:00","dateModified":"2025-05-15T21:20:32+00:00","author":{"@id":"https:\/\/www.polywater.com\/en\/#\/schema\/person\/3734e7b75c8edb79b63ccf415c884f9c"},"description":"Because fiber optic cable is pulled from a reel when being installed underground, it\u2019s important to recognize that there may be undulations...","breadcrumb":{"@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/#primaryimage","url":"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/12\/Duct-undulations.jpg","contentUrl":"https:\/\/www.polywater.com\/wp-content\/uploads\/2021\/12\/Duct-undulations.jpg","width":700,"height":467,"caption":"Laying a fiber optic cable for fast internet, Electricity and telephone cable along a new street. Cable Installation power lines at city street, industrial electricity and communication concept."},{"@type":"BreadcrumbList","@id":"https:\/\/www.polywater.com\/en\/knowledge-hub\/model-and-analysis-of-duct-displacement-factor-in-fiber-optic-cable-pulling-part-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.polywater.com\/en\/"},{"@type":"ListItem","position":2,"name":"Model and Analysis of Duct Displacement Factor in Fiber Optic Cable Pulling\u2014Part 1"}]},{"@type":"WebSite","@id":"https:\/\/www.polywater.com\/en\/#website","url":"https:\/\/www.polywater.com\/en\/","name":"Polywater","description":"Solutions at work.","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.polywater.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.polywater.com\/en\/#\/schema\/person\/3734e7b75c8edb79b63ccf415c884f9c","name":"Sheri Dahlke","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/b3172121d8dd4a15b6c79ef31d9a1e2fa90f220dfe15563ddc1c5c81e2a7939f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/b3172121d8dd4a15b6c79ef31d9a1e2fa90f220dfe15563ddc1c5c81e2a7939f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/b3172121d8dd4a15b6c79ef31d9a1e2fa90f220dfe15563ddc1c5c81e2a7939f?s=96&d=mm&r=g","caption":"Sheri Dahlke"},"url":"https:\/\/www.polywater.com\/en\/knowledge-hub\/author\/sheri-dahlke\/"}]}},"_links":{"self":[{"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/posts\/13501","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/users\/22"}],"replies":[{"embeddable":true,"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/comments?post=13501"}],"version-history":[{"count":0,"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/posts\/13501\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/media\/13506"}],"wp:attachment":[{"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/media?parent=13501"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/categories?post=13501"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/tags?post=13501"},{"taxonomy":"industry-type","embeddable":true,"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/industry-type?post=13501"},{"taxonomy":"writer","embeddable":true,"href":"https:\/\/www.polywater.com\/en\/wp-json\/wp\/v2\/writer?post=13501"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}